OPTIMA Compact EP
Extended Performance DN50-DN200
OPTIMA Compact EP (Extended Performance) pressure independent balancing & control valves (PICVs) are used in applications with high demands for temperature and differential pressure, such as district heating and low-temperature cooling applications. The OPTIMA Compact EP provides modulating control with full authority, regardless of any fluctuations in the system’s differential pressure.
The OPTIMA Compact EP combines an externally adjustable balancing valve, a differential pressure control valve, and a full-authority modulating control valve. This integration makes it simple to achieve 100% control of the flow in the building, enhancing comfort and achieving energy savings simultaneously.
An additional benefit is that no balancing is required when further stages are added to the system or when the dimensioned capacity changes. Energy savings are achieved through optimal control, lower flow, and reduced pump pressure. The maximised ∆T, due to faster response and increased system stability, further contributes to overall efficiency.
Benefits
Design
- Less time to define the necessary equipment for a hydraulic balanced system (only flow data are required)
- No need to calculate valve authority - always one
- Flexibility if the system is modified after the initial installation
Installation
- No further regulating valves required in the distribution pipework when Frese OPTIMA Compact EP is installed at the units
- Total number of valves minimized due to the 3-in-1 design
- Minimized commissioning time due to automatic balancing of the system
- No minimum straight pipe lengths required before or after the valve
Operation
- High comfort for the end-users due to high precision temperature control
- Longer life due to less movements of the actuator
Features
- The valve is specifically engineered to operate efficiently across a wide temperature range, from -10°C to +150°C, ensuring reliable performance in both low and high-temperature environments
- Differential pressure operating range up to 1200 kPa
- The presetting function has no impact on the stroke; Full stroke modulation at all times, regardless the preset flow
- Regulation characteristic remains unchanged regardless of preset flow
- The constant differential pressure across the modulating control component guarantees 100% authority
- Automatic balancing eliminates overflows, regardless of fluctuating pressure conditions in the system
- Motoric actuator 0-10 V, 4-20 mA and 3 point control
- High flows with minimal required differential pressure due to advanced design of the valve
- Small dimensions due to compact housing
- Higher presetting precision due to stepless analogue scale
- Rangeabililty > 100:1
Frese OPTIMA
Performance beyond size
Med stor ydeevne og betydelig energibesparelse, sætter Frese OPTIMA PICV nye standarder indenfor varme- og kølesystemer.
Fuld modulerende kontrol og maksimal ΔT
Med Frese OPTIMA PICV vil du opnå en modulerende regulering med fuld autoritet uafhængigt af enhver variation i anlæggets differenstryk.
Den optimale styring, det lavere flow og det lavere pumpetryk sikrer dig store energibesparelser. Samtidig vil du automatisk maksimere ΔT som følge af den meget hurtigere reaktionstid og øgede systemstabilitet.
Fuld styring af flowet betyder større energibesparelse
Frese OPTIMA PICV gør det nemt at opnå 100% kontrol af flowet i bygningen og skaber samtidig en høj grad af komfort og energibesparelse. Der kræves ingen regulering, hvis yderligere trin føjes til anlægget, eller den dimensionerede kapacitet ændres.
Trykuafhængig strengregulerings- og motorventil
Frese OPTIMA PICV kombinerer en eksternt justerbar dynamisk strengreguleringsventil, en differenstryksregulator samt en modulerende motorventil med fuld autoritet.
Du kan anvende Frese OPTIMA PICV i varme- og køleanlæg i applikationer med fan coil units, airconditionsanlæg samt veksler- og blandesløjfeanlæg.
Fordele
Design
- Mindre tid med at definere det nødvendige udstyr til et hydraulisk reguleret system (kun flow data er nødvendigt).
- Intet behov for at beregne ventilautoritet, da den altid er 1.
- Fleksibilitet hvis systemet ændres efter den første installation.
Installation
- Der kræves ingen yderligere reguleringsventiler i fordelingssystemet, når Frese OPTIMA PICV er installeret ved terminalerne.
- Det samlede antal ventiler minimeres takket være 3-i-1-design.
- Kortere idriftsætningsstid takket være dynamisk indregulering af anlægget.
- Ingen krav til minimumslængde for lige rør før og efter ventilen.
Drift
- Høj komfort for slutbrugeren takket være den meget præcise temperaturregulering.
- Længere levetid pga. færre aktuatorbevægelser.
Funktioner
- Forindstillingsfunktionen har ingen virkning på slaglængden. Der er altid fuld modulation af slaglængden uanset det forindstillede flow.
- Det konstante differenstryk over den modulerende reguleringsenhed garanterer fuld autoritet.
- Dynamisk regulering fjerner overflow uanset trykforholdene i systemet.
- Elektrisk aktuator 0-10 V og 3-punkt-styring.
- Kan operere i differenstrykområder op til 600 kPa.
- Højt flow med lavt differenstryk takket være avanceret ventildesign.
- Mindre dimensioner takket være det kompakte ventilhus.
- Høj forindstillingspræcision takket være den trinløse analoge skala.